CVP verified calculation capability
Compute MOSFET conduction loss from I, Rds(on), current_basis (dc / on-interval RMS / full-cycle MOSFET RMS), and optional Rds(Tj) via linear α or datasheet ratio.
Electrical · Mosfet Capability ID electrical.mosfet.conduction_loss version 1.2.2 CVP VERIFIED CURRENT Engineering
On-interval RMS
P = I_on,rms² × Rds(on) × DP = I_rms² × Rds(on)VDS estimate = I × Rds_TjRds(Tj) = Rds(Tref) × (1 + α × (Tj − Tref))Rds(Tj) = Rds(Tref) × rds_ratioCanonical symbols for this capability. Agent schemas remain the contract.
| Symbol | Quantity | Unit | Role |
|---|---|---|---|
I | Current in amperes | — | input / output |
Rds | On-resistance Rds | — | input / output |
D | Duty cycle fraction in | — | input / output |
current_basis | How I is defined | — | input / output |
temperature_model | Rds | — | input / output |
Tj | Junction temperature | °C | input / output |
Tref | Rds reference temperature | °C | input / output |
alpha_per | Linear temperature coefficient | °C | input / output |
rds_ratio | Normalized Rds | — | input / output |
P | Conduction loss at Rds_Tj | W | output |
V_drop | Resistive voltage drop at the entered current using Rds_Tj: I·Rds_Tj | — | output |
Rds_Tj | Rds used in P_W | — | output |
P_W_ref | Conduction loss at entered Rds / Tref | — | output |
V_drop_ref | I·Rds at Tref | — | output |
Declared scope for this capability. Do not use it outside this domain.
Assumptions
One numerical check. The calculator page holds worked steps and FAQ.
current_basis=dc, I=10, Rds=0.05, rds_ratio=1.44 → P_W=7.2, Rds_Tj=0.072, P_W_ref=5
CVP VERIFIED · CVP protocol 1.0.0-proposed · Engineering assurance. Computational verification is defined by CVP. Supplemental domain review (internal) and named expert review are defined by the Review policy and do not by themselves determine CVP conformance.
Human page, REST, and MCP share the same engine and calculation_version.
Build verified hashes workspace artifacts only. After deploy, attest:production GETs canonical URLs twice — the public/cached view an Agent actually hits, and origin — including every /capabilities/{id} HTML page. Public Capability HTML version must match catalog before production attestation passes. Live Trust rows above fetch /.well-known/calculatorx-production-attestation.json
and the output schema const. Build hashes: release integrity. That proves currently published page / engine / schema / evidence / MCP agree — not that a historical version is independently immutable. Reference Calculation Standard — Production surface contract 14/14.
curl -sS -X POST 'https://www.calculatorx.com/api/v1/calc/mosfet-conduction-loss' \
-H 'Content-Type: application/json' \
-d '{"inputs":{"I":10,"Rds":0.05,"current_basis":"dc"},"calculation_version":"1.2.2"}'{
"inputs": {
"I": 10,
"Rds": 0.05,
"current_basis": "dc"
},
"calculation_version": "1.2.2"
}POST /api/v1/calc/mosfet-conduction-loss. This is a POST calculate endpoint — do not GET it.
Full REST contract: REST API docs.
Declared calculation modes for this capability.
dcon_interval_rmsfull_cycle_rmsHuman-readable sources plus CVP reference evidence classes.
Sources
Reference evidence classes: O1 model · O2 expected_values · O2 numerical_behavior
Inspect, then execute. Same engine as REST and the human calculator.
curl -sS -X POST 'https://www.calculatorx.com/mcp' \
-H 'Content-Type: application/json' \
-H 'MCP-Protocol-Version: 2026-07-28' \
-H 'Mcp-Method: tools/call' \
-H 'Mcp-Name: inspect_capability' \
-d '{"jsonrpc":"2.0","id":1,"method":"tools/call","params":{"name":"inspect_capability","arguments":{"capability_id":"electrical.mosfet.conduction_loss"},"_meta":{"io.modelcontextprotocol/protocolVersion":"2026-07-28","io.modelcontextprotocol/clientInfo":{"name":"calculatorx-docs-example","version":"1.0.0"},"io.modelcontextprotocol/clientCapabilities":{}}}}'curl -sS -X POST 'https://www.calculatorx.com/mcp' \
-H 'Content-Type: application/json' \
-H 'MCP-Protocol-Version: 2026-07-28' \
-H 'Mcp-Method: tools/call' \
-H 'Mcp-Name: execute_calculation' \
-d '{"jsonrpc":"2.0","id":2,"method":"tools/call","params":{"name":"execute_calculation","arguments":{"capability_id":"electrical.mosfet.conduction_loss","inputs":{"I":10,"Rds":0.05,"current_basis":"dc"},"calculation_version":"1.2.2"},"_meta":{"io.modelcontextprotocol/protocolVersion":"2026-07-28","io.modelcontextprotocol/clientInfo":{"name":"calculatorx-docs-example","version":"1.0.0"},"io.modelcontextprotocol/clientCapabilities":{}}}}'Pin calculation_version (1.2.2) when the result must stay reproducible.
Inspect the trust tier and required assurance level before execution. Full protocol notes: MCP docs.