Home Developers Capabilities Power factor

Verified calculation capability

Power factor Calculation Capability

Compute apparent power S, power factor λ, and reactive power Q from RMS V, I, and real power P for 1φ or balanced 3φ. · Electrical

Capability ID electrical.power_factor · version 1.5.1

Model

Power factor

Solve modes: single · three-ll · three-ln

Inputs / Outputs

Canonical symbols for this capability. Agent schemas remain the contract.

SymbolQuantityUnitRole
VRMS volts; L-L or L-N per modeinput
IRMS currentinput
P_kWReal power in kilowattsinput
fOptional frequencyinput
SApparent poweroutput
pfPower factor λ = P/Soutput
QReactive poweroutput

Assumptions / Validity

Declared scope for this capability. Do not use it outside this domain.

Assumptions

Example

One numerical check. The calculator page holds worked steps and FAQ.

230 V, 10 A, 1.8 kW, 1φ → PF ≈ 0.783, S = 2.3 kVA

Open this example in the calculator

Trust

CVP VERIFIED · CVP protocol 1.0.0-proposed · Engineering assurance. Computational verification is defined by CVP. Supplemental domain review (internal) and named expert review are defined by the Review policy and do not by themselves determine CVP conformance.

CVP
CVP VERIFIED · CVP protocol 1.0.0-proposed · Engineering assurance· View Manifest · CVP overview · Specification
Assurance
Engineering
Declared partition coverage
PASS · 4/4 declared partitions (1phi, 3phi-ll, 3phi-ln, invalid-domain)
Calculation version
1.5.1
Verification
26/26 calculation tests · 10/10 legacy golden · 8/8 legacy boundary · 8/8 legacy property
Production surface contract
6/6
Versions
Calculation 1.5.1 · CVP protocol 1.0.0-proposed
CVP identity
8/8 property · digest de0acc0d8167
Reference
O1 model · O2 expected_values · O2 numerical_behavior
Interfaces
PASS · UI (SSR) / REST / MCP
ui-ssr is query-result HTML, not a live browser session.
CVP suite
4/4 golden · 7/7 CVP boundary · 8/8 invalid · 8/8 property · 1/1 cross-interface · 4/4 CVP contract
Supplemental domain review
Not performed
Named expert review
Not performed
Version lock
Supported (409 VERSION_MISMATCH)
Artifact consistency
Build verified · 1.5.1 (workspace artifacts agree)
Review-policy tier
Engine tested — catalog token engine_tested; supplemental; not CVP status
This calculator CURRENT · Public schema 1.5.1 matches · Semantic contract ✓ · Production attested · Public/cache ✓ · Origin ✓

Call this capability

Human page, REST, and MCP share the same engine and calculation_version. Build verified hashes workspace artifacts only. After deploy, attest:production GETs canonical URLs twice — the public/cached view an Agent actually hits, and origin — including every /capabilities/{id} HTML page. Public Capability HTML version must match catalog before production attestation passes. Live Trust rows above fetch /.well-known/calculatorx-production-attestation.json and the output schema const. Build hashes: release integrity. That proves currently published page / engine / schema / evidence / MCP agree — not that a historical version is independently immutable. Reference Calculation Standard — Production surface contract 6/6.

Tool id
power-factor
Engine
power-factor
REST
POST /api/v1/calc/power-factor
MCP
execute_calculation with capability_id: "electrical.power_factor"
Agent input schema
Canonical (MCP / Agent)
Output schema
JSON Schema (latest)
Versioned input schema
Immutable pin (1.5.1)
Versioned output schema
Immutable pin (1.5.1)

Operations

Declared calculation modes for this capability.

References

Human-readable sources plus CVP reference evidence classes.

Sources

Reference evidence classes: O1 model · O2 expected_values · O2 numerical_behavior

Try with an agent

Inspect this capability via same-origin MCP, then call execute_calculation.

curl -sS -X POST 'https://www.calculatorx.com/mcp' \
  -H 'Content-Type: application/json' \
  -H 'MCP-Protocol-Version: 2026-07-28' \
  -H 'Mcp-Method: tools/call' \
  -H 'Mcp-Name: inspect_capability' \
  -d '{"jsonrpc":"2.0","id":1,"method":"tools/call","params":{"name":"inspect_capability","arguments":{"capability_id":"electrical.power_factor"}}}'

Inspect the trust tier and required assurance level before execution. Pin calculation_version (1.5.1) when reproducibility matters. Full protocol notes: MCP docs.