CVP verified calculation capability
Estimate conductor voltage drop from current, one-way length, and Ω/km for DC / resistive 1φ or balanced 3φ (resistance-only, PF≈1). Always returns conductor I²R loss P_loss. Optional V_system adds percent drop and estimated load voltage; optional u_* compose expanded uncertainty on V_drop via Uncertainty Engine.
Electrical Capability ID electrical.voltage_drop version 1.5.2 CVP VERIFIED CURRENT Engineering
One-way resistance
R = L(m) × Rₖₘ / 1000Vdrop = I × 2RVdrop = √3 × I × R%drop = 100 × Vdrop / VsystemPloss = I² × 2RPloss = 3 × I² × RModes: dc · three
Canonical symbols for this capability. Agent schemas remain the contract.
| Symbol | Quantity | Unit | Role |
|---|---|---|---|
I | Load current | — | input |
length | One-way conductor length | m | input |
R_ohm_per | Conductor resistance | km | input |
V_system | Optional source voltage | — | input |
u_I | Optional standard uncertainty of I | — | input |
u_length | Optional standard uncertainty of length_m | m | input |
u_R_ohm_per | Optional standard uncertainty of R_ohm_per_km | km | input |
uncertainty_k | Coverage factor for expanded U on V_drop; default 2 when any u_* is set | — | input |
confidence | Optional coverage probability instead of uncertainty_k | — | input |
V_drop | Estimated voltage drop | — | output |
R_one_way | One-way conductor resistance | — | output |
R_loop | Go-and-return loop resistance | — | output |
P_loss | Conductor I²R loss | — | output |
percent_drop | Present when V_system is set: 100·V_drop/V_system | — | output |
V_load | Present when V_system is set: estimated load voltage V_system − V_drop | — | output |
uncertainty | Present when any u_* is provided; UncertaintySummary via engineering | — | output |
Declared scope for this capability. Do not use it outside this domain.
Assumptions
One numerical check. The calculator page holds worked steps and FAQ.
20 A, 50 m, 5 Ω/km, DC / resistive 1φ, V_system=230 → V_drop = 10, percent_drop ≈ 4.35%, V_load = 220, P_loss = 200
CVP VERIFIED · CVP protocol 1.0.0-proposed · Engineering assurance. Computational verification is defined by CVP. Supplemental domain review (internal) and named expert review are defined by the Review policy and do not by themselves determine CVP conformance.
Human page, REST, and MCP share the same engine and calculation_version.
Build verified hashes workspace artifacts only. After deploy, attest:production GETs canonical URLs twice — the public/cached view an Agent actually hits, and origin — including every /capabilities/{id} HTML page. Public Capability HTML version must match catalog before production attestation passes. Live Trust rows above fetch /.well-known/calculatorx-production-attestation.json
and the output schema const. Build hashes: release integrity. That proves currently published page / engine / schema / evidence / MCP agree — not that a historical version is independently immutable. Reference Calculation Standard — Production surface contract 8/8.
curl -sS -X POST 'https://www.calculatorx.com/api/v1/calc/voltage-drop' \
-H 'Content-Type: application/json' \
-d '{"inputs":{"mode":"dc","I":20,"length_m":50,"R_ohm_per_km":5},"calculation_version":"1.5.2"}'{
"inputs": {
"mode": "dc",
"I": 20,
"length_m": 50,
"R_ohm_per_km": 5
},
"calculation_version": "1.5.2"
}POST /api/v1/calc/voltage-drop. This is a POST calculate endpoint — do not GET it.
Full REST contract: REST API docs.
Declared calculation modes for this capability.
dcthreeHuman-readable sources plus CVP reference evidence classes.
Sources
Reference evidence classes: O1 model · O2 expected_values · O2 numerical_behavior
Inspect, then execute. Same engine as REST and the human calculator.
curl -sS -X POST 'https://www.calculatorx.com/mcp' \
-H 'Content-Type: application/json' \
-H 'MCP-Protocol-Version: 2026-07-28' \
-H 'Mcp-Method: tools/call' \
-H 'Mcp-Name: inspect_capability' \
-d '{"jsonrpc":"2.0","id":1,"method":"tools/call","params":{"name":"inspect_capability","arguments":{"capability_id":"electrical.voltage_drop"},"_meta":{"io.modelcontextprotocol/protocolVersion":"2026-07-28","io.modelcontextprotocol/clientInfo":{"name":"calculatorx-docs-example","version":"1.0.0"},"io.modelcontextprotocol/clientCapabilities":{}}}}'curl -sS -X POST 'https://www.calculatorx.com/mcp' \
-H 'Content-Type: application/json' \
-H 'MCP-Protocol-Version: 2026-07-28' \
-H 'Mcp-Method: tools/call' \
-H 'Mcp-Name: execute_calculation' \
-d '{"jsonrpc":"2.0","id":2,"method":"tools/call","params":{"name":"execute_calculation","arguments":{"capability_id":"electrical.voltage_drop","inputs":{"mode":"dc","I":20,"length_m":50,"R_ohm_per_km":5},"calculation_version":"1.5.2"},"_meta":{"io.modelcontextprotocol/protocolVersion":"2026-07-28","io.modelcontextprotocol/clientInfo":{"name":"calculatorx-docs-example","version":"1.0.0"},"io.modelcontextprotocol/clientCapabilities":{}}}}'Pin calculation_version (1.5.2) when the result must stay reproducible.
Inspect the trust tier and required assurance level before execution. Full protocol notes: MCP docs.