CVP verified calculation capability
1-D RSS or worst-case tolerance stack — Basic tol list or Engineering dimensions (nominal, ±tol, direction).
Engineering · Tolerance Capability ID engineering.tolerance.stackup version 1.4.0 CVP VERIFIED CURRENT Engineering
Worst case (Basic)
stack = Σ|tol_i|stack_worst = max(stack_worst_plus, stack_worst_minus)stack = √Σ u_i²stack_nom = Σ s_i · nom_iModes: rss · worst case
Canonical symbols for this capability. Agent schemas remain the contract.
| Symbol | Quantity | Unit | Role |
|---|---|---|---|
tol | Basic mode: tolerance contributions | — | input / output |
tol1 | — | — | input |
tol2 | — | — | input |
tol3 | — | — | input |
tol4 | — | — | input |
tol5 | — | — | input |
tol6 | — | — | input |
tol7 | — | — | input |
tol8 | — | — | input |
dimensions | Engineering mode: named dimensions with nominal, asymmetric ±tol, direction, and statistical_basis | — | input / output |
profile | — | — | output |
n | — | — | output |
stack | — | — | output |
stack_rss | — | — | output |
stack_worst | Scalar worst-case = max | — | output |
stack_worst_plus | stack_max − stack_nom | — | output |
stack_worst_minus | stack_nom − stack_min | — | output |
stack_range | stack_max − stack_min = worst_plus + worst_minus | — | output |
stack_half_range | stack_range / 2 — not the same as stack_worst when asymmetric | — | output |
stack_nom | — | — | output |
stack_stat_center | Engineering: signed stack using uniform midpoints where statistical_basis=uniform; equals stack_nom otherwise | — | output |
stack_center_shift | stack_stat_center − stack_nom | — | output |
stack_min | — | — | output |
stack_max | — | — | output |
rss_over_wca | — | — | output |
Declared scope for this capability. Do not use it outside this domain.
Assumptions
Not supported
One numerical check. The calculator page holds worked steps and FAQ.
Engineering A10+0.05/−0.15 − B5±0.2 + C3±0.1 → nom=8, W−=0.45, W+=0.35, stack_worst=0.45, RSS≈0.245
CVP VERIFIED · CVP protocol 1.0.0-proposed · Engineering assurance · Basic RSS/WCA + Engineering dimensions[] + O3 mpmath tabulated RSS/WCA. Computational verification is defined by CVP. Supplemental domain review (internal) and named expert review are defined by the Review policy and do not by themselves determine CVP conformance.
Human page, REST, and MCP share the same engine and calculation_version.
Build verified hashes workspace artifacts only. After deploy, attest:production GETs canonical URLs twice — the public/cached view an Agent actually hits, and origin — including every /capabilities/{id} HTML page. Public Capability HTML version must match catalog before production attestation passes. Live Trust rows above fetch /.well-known/calculatorx-production-attestation.json
and the output schema const. Build hashes: release integrity. That proves currently published page / engine / schema / evidence / MCP agree — not that a historical version is independently immutable. Reference Calculation Standard — Production surface contract 10/10.
curl -sS -X POST 'https://www.calculatorx.com/api/v1/calc/tolerance-stackup' \
-H 'Content-Type: application/json' \
-d '{"inputs":{"mode":"rss","tol":[0.1,0.2,0.1]},"calculation_version":"1.4.0"}'{
"inputs": {
"mode": "rss",
"tol": [
0.1,
0.2,
0.1
]
},
"calculation_version": "1.4.0"
}POST /api/v1/calc/tolerance-stackup. This is a POST calculate endpoint — do not GET it.
Full REST contract: REST API docs.
Declared calculation modes for this capability.
rssworst_caseHuman-readable sources plus CVP reference evidence classes.
Sources
Reference evidence classes: O1 model · O3 expected_values · O3 numerical_behavior · O2 expected_values · O2 numerical_behavior
Inspect, then execute. Same engine as REST and the human calculator.
curl -sS -X POST 'https://www.calculatorx.com/mcp' \
-H 'Content-Type: application/json' \
-H 'MCP-Protocol-Version: 2026-07-28' \
-H 'Mcp-Method: tools/call' \
-H 'Mcp-Name: inspect_capability' \
-d '{"jsonrpc":"2.0","id":1,"method":"tools/call","params":{"name":"inspect_capability","arguments":{"capability_id":"engineering.tolerance.stackup"},"_meta":{"io.modelcontextprotocol/protocolVersion":"2026-07-28","io.modelcontextprotocol/clientInfo":{"name":"calculatorx-docs-example","version":"1.0.0"},"io.modelcontextprotocol/clientCapabilities":{}}}}'curl -sS -X POST 'https://www.calculatorx.com/mcp' \
-H 'Content-Type: application/json' \
-H 'MCP-Protocol-Version: 2026-07-28' \
-H 'Mcp-Method: tools/call' \
-H 'Mcp-Name: execute_calculation' \
-d '{"jsonrpc":"2.0","id":2,"method":"tools/call","params":{"name":"execute_calculation","arguments":{"capability_id":"engineering.tolerance.stackup","inputs":{"mode":"rss","tol":[0.1,0.2,0.1]},"calculation_version":"1.4.0"},"_meta":{"io.modelcontextprotocol/protocolVersion":"2026-07-28","io.modelcontextprotocol/clientInfo":{"name":"calculatorx-docs-example","version":"1.0.0"},"io.modelcontextprotocol/clientCapabilities":{}}}}'Pin calculation_version (1.4.0) when the result must stay reproducible.
Inspect the trust tier and required assurance level before execution. Full protocol notes: MCP docs.