Home Developers Evidence physics.fluid.iso_venturi

Public evidence

physics.fluid.iso_venturi

Machine-checked verification for calculation version 1.0.0 · tier engine_tested

Verification

5/5 calculation tests · Production surface contract 1/1

  • Golden tests 0 / 0
  • Boundary tests 0 / 0
  • Property tests 5 / 5
  • Production surface contract 1 / 1
  • }
  • Engine tested Yes
  • Source checked Yes
  • Artifact integrity PASS
  • Production attestation Embedded snapshot: STALE · Last attested schema matched 1.0.0 snapshot / local build · Semantic contract ✓ · Last attestation PASS · current evidence changed · re-attestation required · Public/cache ✓ · Origin ✓ · Live production status PASS (0 stale; 164 CURRENT) @ 2026-09-18T02:44:05.986Z
  • Semantic contract PASS
  • Evidence attested at 2026-09-18T02:44:05.231Z
  • Last production check 2026-09-18T02:44:05.231Z
  • Public / cache PASS
  • Origin PASS
  • Supplemental domain review Not performed
  • Named expert review Not performed
  • release artifacts aligned PASS

Fingerprint sha256:161f5369b562d37af9a5fca26cda9e3a47228ba90679f1788b27f98e9ea804e0

Input schema sha256:34a7b4bf9eb9c529cbb3db84c9b95e6110b6022113413870dc19c1bb59511405 · Output schema sha256:1c709535e6fb11daae178a62b27d70707d7f345f9425433bb407c903ae709632 · Build-time SHA-256 digests prove published artifacts agree with each other (release_integrity.scope=workspace). Production attestation GETs canonical URLs twice (public/cached view and origin), including Capability HTML, via npm run attest:production --write (published at /.well-known/calculatorx-production-attestation.json) and fails if the public Capability page advertises a different calculation_version. This is artifact consistency, not an independent immutable release log.

Build & scope

Engine identity and declared limitations.

Tool
iso-venturi
Engine
iso-venturi
Engine build
2026-09-18
Evidence core
2026-09-18T00:57:14.019Z
Rendered
2026-09-18T03:31:40.488Z
Last reviewed

Assumptions

  • ISO 5167-4 classical Venturi tube: Q = C E A2 √(2Δp/ρ); C from convergent type; β and Re_D bound the ISO envelope; incompressible ε=1; C is reported, not an input
  • Machined C=0.995, D∈[50 mm,250 mm], β∈[0.40,0.75], Re_D∈[2e5,1e6]. Rough-welded C=0.985. As-cast C=0.984
  • Not a given C_d=0.98, not ISA 1932 nozzle, not RHG orifice, not Q=Av, not Darcy f, not compressible ε

Limitations

  • ISO 5167-4 classical Venturi tube: Q = C E A2 √(2Δp/ρ); C from convergent type; β and Re_D bound the ISO envelope; incompressible ε=1; C is reported, not an input
  • Machined C=0.995, D∈[50 mm,250 mm], β∈[0.40,0.75], Re_D∈[2e5,1e6]. Rough-welded C=0.985. As-cast C=0.984
  • Not a given C_d=0.98, not ISA 1932 nozzle, not RHG orifice, not Q=Av, not Darcy f, not compressible ε

Sources

Standards and references supporting this tool specification. Methods are listed separately — they are algorithms, not bibliographic sources.

Published checks

Golden, boundary, and property cases included in this evidence build.

IDKindStatusDetail
property-vtu-Cpropertypassmachined C=0.995
property-vtu-QpropertypassQ=C E A2 √(2Δp/ρ)
property-vtu-not-098propertypassC≠0.98
property-vtu-roundtrip-dPpropertypassΔp invert
property-vtu-modelpropertypassiso_5167_4_classical