Verification
5/5 calculation tests · Production surface contract 1/1
- Golden tests 0 / 0
- Boundary tests 0 / 0
- Property tests 5 / 5
- Production surface contract 1 / 1
}
- Engine tested Yes
- Source checked Yes
- Artifact integrity PASS
- Production attestation Embedded snapshot: STALE · Last attested schema matched 1.0.0 snapshot / local build · Semantic contract ✓ · Last attestation PASS · current evidence changed · re-attestation required · Public/cache ✓ · Origin ✓ · Live production status PASS (0 stale; 164 CURRENT) @ 2026-09-18T02:44:05.986Z
- Semantic contract PASS
- Evidence attested at 2026-09-18T02:44:05.231Z
- Last production check 2026-09-18T02:44:05.231Z
- Public / cache PASS
- Origin PASS
- Supplemental domain review Not performed
- Named expert review Not performed
- release artifacts aligned PASS
Fingerprint sha256:161f5369b562d37af9a5fca26cda9e3a47228ba90679f1788b27f98e9ea804e0
Input schema sha256:34a7b4bf9eb9c529cbb3db84c9b95e6110b6022113413870dc19c1bb59511405 · Output schema sha256:1c709535e6fb11daae178a62b27d70707d7f345f9425433bb407c903ae709632 · Build-time SHA-256 digests prove published artifacts agree with each other (release_integrity.scope=workspace). Production attestation GETs canonical URLs twice (public/cached view and origin), including Capability HTML, via npm run attest:production --write
(published at /.well-known/calculatorx-production-attestation.json) and fails if the public Capability page advertises a different calculation_version. This is artifact consistency, not an independent immutable release log.
Engine identity and declared limitations.
- Tool
- iso-venturi
- Engine
- iso-venturi
- Engine build
- 2026-09-18
- Evidence core
- 2026-09-18T00:57:14.019Z
- Rendered
- 2026-09-18T03:31:40.488Z
- Last reviewed
- —
Assumptions
- ISO 5167-4 classical Venturi tube: Q = C E A2 √(2Δp/ρ); C from convergent type; β and Re_D bound the ISO envelope; incompressible ε=1; C is reported, not an input
- Machined C=0.995, D∈[50 mm,250 mm], β∈[0.40,0.75], Re_D∈[2e5,1e6]. Rough-welded C=0.985. As-cast C=0.984
- Not a given C_d=0.98, not ISA 1932 nozzle, not RHG orifice, not Q=Av, not Darcy f, not compressible ε
Limitations
- ISO 5167-4 classical Venturi tube: Q = C E A2 √(2Δp/ρ); C from convergent type; β and Re_D bound the ISO envelope; incompressible ε=1; C is reported, not an input
- Machined C=0.995, D∈[50 mm,250 mm], β∈[0.40,0.75], Re_D∈[2e5,1e6]. Rough-welded C=0.985. As-cast C=0.984
- Not a given C_d=0.98, not ISA 1932 nozzle, not RHG orifice, not Q=Av, not Darcy f, not compressible ε
Sources
Standards and references supporting this tool specification. Methods are listed separately — they are algorithms, not bibliographic sources.
Published checks
Golden, boundary, and property cases included in this evidence build.
| ID | Kind | Status | Detail |
|---|
property-vtu-C | property | pass | machined C=0.995 |
property-vtu-Q | property | pass | Q=C E A2 √(2Δp/ρ) |
property-vtu-not-098 | property | pass | C≠0.98 |
property-vtu-roundtrip-dP | property | pass | Δp invert |
property-vtu-model | property | pass | iso_5167_4_classical |