Verified calculation capability
ISO 5167-2 orifice plate Q=C E A2 √(2Δp/ρ) with Reader–Harris/Gallagher C from β, Re_D, and tapping. Not tank orifice C_d A √(2gH), not given C_d=0.61, not ISA 1932, not venturi C_d=0.98, not Q=Av, not Darcy. · Physics · Fluid
Capability ID physics.fluid.iso_orifice · version 1.0.0
Discharge
Q = C E A2 √(2Δp / ρ)β = d/D · E = 1/√(1 − β⁴)C = 0.5961 + 0.0261 β² − 0.216 β⁸ + 0.000521 (10⁶ β / Re_D)^0.7 + (0.0188 + 0.0063 A) β^3.5 (10⁶ / Re_D)^0.3Solve modes: flow · pressure · coefficient
Canonical symbols for this capability. Agent schemas remain the contract.
| Symbol | Quantity | Unit | Role |
|---|---|---|---|
D | Pipe diameter in m. Required. D in [0.05, 1.0]. Alternative: D_m, pipe_D. Do not send D1+D2. | — | input / output |
d | Bore diameter in m. Required unless beta. d ≥ 0.0125 m. Alternatives: d_m, bore, D_bore. Do not mix with beta. | — | input / output |
beta | d/D in [0.10, 0.75]. Alternative to d. Alternative: diameter_ratio. | — | input / output |
Re_D | Pipe Reynolds number on D. Required. ≥5000 (β≤0.56) or 16000 β² (β>0.56). Alternatives: Re, ReD. Do not send ρ, μ, v. | — | input / output |
tapping | corner (default) or flange. D-D/2 is out of scope. Alternatives: taps, tap. | — | input / output |
dP | Upstream-to-vena differential pressure in Pa. Required for flow. Alternatives: deltaP, dP_Pa, dp. | — | input / output |
rho | Density in kg/m³. Required for flow and pressure. | — | input / output |
Q | Volume flow in m³/s. Required for pressure invert. Alternative: flow, Q_m3_s. | — | input / output |
E | — | — | output |
A1 | — | — | output |
A2 | — | — | output |
C | — | — | output |
Cd | — | — | output |
v1 | — | — | output |
v2 | — | — | output |
model | — | — | output |
Declared scope for this capability. Do not use it outside this domain.
Assumptions
Not supported
One numerical check. The calculator page holds worked steps and FAQ.
D=0.1 d=0.05 Re_D=1e6 dP=10000 rho=1000 corner → C≈0.60378 Q≈0.005476
Review-policy: engine tested — automated tests, sources, version lock, and evidence published. Supplemental to CVP; not Domain Expert Review. See CVP and Review policy.
Human page, REST, and MCP share the same engine and calculation_version.
Build verified hashes workspace artifacts only. After deploy, attest:production GETs canonical URLs twice — the public/cached view an Agent actually hits, and origin — including every /capabilities/{id} HTML page. Public Capability HTML version must match catalog before production attestation passes. Live Trust rows above fetch /.well-known/calculatorx-production-attestation.json
and the output schema const. Build hashes: release integrity. That proves currently published page / engine / schema / evidence / MCP agree — not that a historical version is independently immutable. Production surface contract 1/1.
Human-readable sources plus CVP reference evidence classes.
Sources
Inspect this capability via same-origin MCP, then call execute_calculation.
curl -sS -X POST 'https://www.calculatorx.com/mcp' \
-H 'Content-Type: application/json' \
-H 'MCP-Protocol-Version: 2026-07-28' \
-H 'Mcp-Method: tools/call' \
-H 'Mcp-Name: inspect_capability' \
-d '{"jsonrpc":"2.0","id":1,"method":"tools/call","params":{"name":"inspect_capability","arguments":{"capability_id":"physics.fluid.iso_orifice"}}}'
Inspect the trust tier and required assurance level before execution. Pin calculation_version (1.0.0) when reproducibility matters. Full protocol notes: MCP docs.